INSTALLING THE USB CROSSMATCH VERIFIER

INSTALLING THE USB CROSSMATCH VERIFIER

USB Support For The Crossmatch Verifier Was Added With Scrap Dragon Version 6.4i

Do not plug in the Verifier until the USB_SDK software has been installed and the system rebooted.

  1. Download the “USB SDK for Verifier 300LC and 310LC” from the Crossmatch web site. USB-SDKS 3-1.zip
  2. Extract the files to a known folder and run setup. Choose Minimum Install.
  3. Reboot the computer.
  4. Plug in the USB verifier.
  5. Copy Crossmatchslave.exe from the dragonsetupdriverscrossmatch folder on the server into the local dragon folder (usually c:dragonlocal). Copy USB4xxx.dll from the Program FilesCrossmatch folder into the local dragon folder (usually c:dragonlocal).
  6. Create a folder on the server for the temporary fingerprint images from THIS verifier. If there is more than one USB verifier on the network, then each verifier will need its own folder on the server.
  7. In JPEGger, add a camera for THIS verifier, use the camera type ‘Directory’ and specify the directory name from step 6 above.
  8. In Scrap Dragon; back office; maintenance; setup; local computer options; imaging tab. Enter the name of the Fingerprint camera from step 7 above. Click USB and enter the path name to the camera directory from step 6 above. Click “Close” and/or “Pay” to specify when fingerprints will be captured.

ATTACHMENT/DOWNLOAD LINK

USB Crossmatch Verifier (USB_SDK5-3-1.zip)

    • Related Articles

    • Gemalto with USB error in Device Manager

      per George: Had a lot of trouble getting a Gemalto to work at a new yard with a new computer yesterday. Gemalto has blue light as if it was working but in device manager it had a USB error. Seemed like it was finicky with the USB or power coming from ...
    • ASSIGNING STATIC IP ADDRESS TO CROSSMATCH VERIFIER 300E

      JPEGger requires that a Static IP Address be setup for the Crossmatch Verifier 300E. With multiple verifiers on a network, this can be a problem if the setup is done improperly. When the Verifier is attached to the network, it will be assigned a DHCP ...
    • Installing a Desko Icon Passport Snapshell Scanner P5

      Instructions for installing the P5 scanner in Scrap Dragon Classic only, It is currently unsupported in SDX. The installation is straight forward. Login as an administrator. Install the latest Acuant SDK and make sure to check the boxes for both the ...
    • INSTALLING THE FUJITSU S510, S1500 TITLE SCANNER

      Fujitsu S510, S1500 Install the scan snap manager only, then attach the scanner. I did the minimum install but you might want to also install the full version of adobe acrobat that comes with the scanner. During the install you will be prompted for: ...
    • How to install a Secugen Hamster Fingerprint Reader

      The Secugen Hamster Fingerprint Reader was introduced as a lower cost alternative to the Crossmatch Verifier.  There are 2 versions of the hamster and each requires a different driver installation package. Installation Instructions In Windows Unzip ...