Unable to obtain a valid reading from the scale

Unable to obtain a valid reading from the scale

When using a USB to Serial Adapter to connect to a scale indicator, you may intermittently get the following error when attempting to read the scale:

Unable to obtain a valid reading from the scale.  Error: The I/O operation has been aborted because of either a thread exit or an application request.

This can be resolved by adjusting the USB Transfer Sizes from the default value of 4096 to something lower eg. 2048.  The setting can be found in the device manager properties for the USB Adapter, Port Settings, Advanced.
    • Related Articles

    • How to interface an electronic scale.

      See the attached document for instructions
    • Scale Weigh with Bobtail

      Step 1: Truck 1 weighs in: select commodity and Gross in at 80,000 Step 2: Truck 1 weighs out: select a commodity again (thus creating a new line item) and Tare out at 24,000. (*OPTIONAL step 2: create a menu button called "bobtail + commodity name" ...
    • HOW TO OBTAIN A MAC ADDRESS

      From the command prompt, type the following command: ipconfig /all This will give you a list of all network adapters (NICs, Bluetooth devices, connected VPNs, etc.). You are looking for the adapter that is bound to the current IP address of the PC. ...
    • Unable to open file error Messages when logging on to Scrap Dragon

      There can be a variety of reasons that Scrap Dragon might not be able to open all of its files.  Most common are issues with the network, permission issues, and corrupt files. Make sure that the network dragon folder is shared and everyone has full ...
    • HOW TO SETUP SCRAP DRAGON FOR GEORGIA SCRAP LAWS

      Compliance With The 2012 Georgia Scrap Laws Requires Scrap Dragon Version 7.0 Or Later And Jpegger Version 2.0 Or Later Scrap Dragon can help you comply with the new requirements as follows: Documentation and record keeping Payment restrictions ...